All existing content moved from repo root into proxmox/ to make room for other Debian machine configs. Adds pihole/ with: - config/pihole.toml — snapshot of current Pi-hole v6 config - config/dnsmasq.d/99-ipxe-chainload.conf — custom PXE DHCP rules (EFI/BIOS iPXE chainload, fixed tag-specificity bug for UEFI boot) - pull-config.sh <source-host> <dest-dir> — pull live config to disk - apply-config.sh <source-dir> <dest-host> — push config to a Pi-hole Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01XRzqNDrbnYR22ZgZj1Bg3s
67 lines
3.0 KiB
Markdown
67 lines
3.0 KiB
Markdown
# Storage: LVM-thin → ZFS → Ceph
|
|
|
|
**Stage 2 (future).** Describes the target storage model once dedicated
|
|
cluster hardware exists. `pve1`'s current single ZFS mirror (boot + VM
|
|
storage combined, see `01-hardware-node1.md`) is the Stage 1 end state for
|
|
now, not an intermediate step being actively migrated from.
|
|
|
|
## Why move off LVM-thin
|
|
|
|
Neither ZFS nor LVM-thin is shared storage — both are node-local. HA needs
|
|
a VM's disk reachable from more than one node so it can restart elsewhere
|
|
on host failure. LVM-thin has no answer for that. Ceph does, natively.
|
|
|
|
## Storage model: single node → 3-node cluster
|
|
|
|
No intermediate "ZFS + replication" HA step. The plan is deliberately a
|
|
single storage model at the end (Ceph), not two to operate long-term:
|
|
|
|
- **Single node (node 1 only)**: local ZFS pool, no cluster-wide HA. This
|
|
is a temporary state, not a design to build tooling around.
|
|
- **3 nodes with Ceph live**: VMs run on Ceph-backed storage — true
|
|
distributed, synchronous storage across all nodes, near-zero RPO on
|
|
failover. Needs 3+ nodes and a fast dedicated network (see
|
|
`03-networking.md`), which is exactly why it can't exist before then.
|
|
|
|
## Migration plan (old hardware → new hardware)
|
|
|
|
Don't convert the old LVM-thin box in place. Rebuild fresh on new
|
|
hardware with ZFS from the installer (mirror if 2+ disks), then move VMs:
|
|
|
|
1. On the old host: `vzdump` each VM to a backup file (external drive,
|
|
NFS share, or PBS if available).
|
|
2. Copy backups to the new host.
|
|
3. `qmrestore` onto the new ZFS storage — disks land as ZVOLs.
|
|
|
|
Alternative if both hosts can see each other on the network: temporarily
|
|
cluster them and use the GUI "Migrate" with a storage move (offline only
|
|
— live migration doesn't cross storage types).
|
|
|
|
## Standing up Ceph once nodes 2 and 3 exist
|
|
|
|
1. Wipe the temporary local ZFS pool on the Ceph-earmarked disks (see
|
|
`01-hardware-node1.md`) on all 3 nodes — they need to end up raw,
|
|
unformatted.
|
|
2. Install the Ceph packages on all 3 nodes (`pveceph install`) and
|
|
initialize the cluster (`pveceph init`), using the dedicated Ceph
|
|
network from `03-networking.md`.
|
|
3. Create Ceph monitors and managers (3 mons for quorum, matching node
|
|
count).
|
|
4. Create OSDs directly on the raw disks on each node — no ZFS/RAID
|
|
underneath.
|
|
5. Create a Ceph pool sized for your VM storage needs (replica count,
|
|
typically 3 for full redundancy across 3 nodes).
|
|
6. Add the pool as PVE storage (RBD), then migrate VMs from local ZFS
|
|
onto it — offline migration if crossing storage types, or storage
|
|
migration via the GUI.
|
|
7. Configure HA groups once VMs are on Ceph-backed storage.
|
|
|
|
## Notes
|
|
|
|
- Ceph RAM/CPU overhead is real — budget per `01-hardware-node1.md`
|
|
(roughly 3-5GB RAM and a core per OSD, on top of VM workloads).
|
|
- Enterprise SSDs with power-loss protection (PLP) matter far more here
|
|
than for plain ZFS — Ceph write latency is sensitive to it.
|
|
- Once Ceph is live, local ZFS remains only for each node's boot pool —
|
|