Simplifies the storage model to one long-term tier (Ceph) instead of two. Node 1 runs local ZFS only until nodes 2/3 join, at which point Ceph goes live and VMs migrate onto it directly.
2.8 KiB
Node 1 Hardware Layout
Build node 1 so nodes 2/3 are drop-in identical later — don't re-architect disks or network when the cluster grows.
Disks — two roles, physically separate devices
- Boot/OS pool (
rpool) — 2x small SSDs (240-480GB plenty), ZFS mirror. Proxmox itself only. Never share with Ceph OSDs. - Future Ceph OSD disks — must end up as raw, unformatted devices —
no ZFS/RAID/LVM underneath (Ceph does its own replication; anything
underneath just doubles copy-on-write/checksumming and hurts
performance). Use enterprise SATA/NVMe SSDs with power-loss protection
(PLP) — matters far more for Ceph write latency than for general ZFS
use. Ceph needs 3 nodes minimum to go live, so on node 1 these disks
either sit idle or run as a temporary local ZFS pool (all VMs live
here until nodes 2/3 exist), to be wiped and handed to Ceph once the
cluster can actually run it. See
02-storage-zfs-ceph.md.
No permanent local-ZFS "replicated tier" — once Ceph is live, it's the only HA storage; local ZFS is boot pool + this temporary pre-Ceph staging role, not an ongoing parallel tier. Avoid consumer QLC SSDs for either role — Ceph punishes it on latency, ZFS on sync writes/scrub.
Networking — cable and provision for the final topology now
Logically separate networks (ideally separate NICs/VLANs):
- Management — web UI / SSH
- Corosync — cluster quorum traffic, low-latency, unshared
- Ceph public — VM-to-OSD traffic
- Ceph cluster/backend — OSD-to-OSD replication (heaviest load)
Practical layout: 2x 10/25GbE bonded or split — one pair for Ceph, one for mgmt + corosync + VM traffic, with corosync on its own VLAN even if sharing a physical NIC. Get switch/cabling right on node 1 so nodes 2/3 are identical drops.
CPU / RAM sizing
Size for the end state, not day one — RAM is the hardest thing to retrofit. Budget covers:
- OS + ZFS ARC (ZFS wants RAM, not just disk)
- Ceph OSD daemons — realistically 3-5GB per OSD once running
- Actual VM workloads
Roughly a core per OSD on top of what VMs need. If OSDs won't be active for a while, that's headway, but buy for 3 nodes' worth of eventual OSD load.
Backup target (PBS)
Keep it off the Ceph/compute nodes if possible — its failure domain should be independent of the cluster. Modest separate machine or NAS: ZFS mirror or raidz2, ECC RAM if possible, capacity for retention policy. If it has to run as a VM inside the cluster short-term, that's a known compromise, not the end state.
Node 1 install sequence
- Install Proxmox VE fresh onto the ZFS boot mirror.
- Provision the Ceph-earmarked disks as a temporary local ZFS pool and run all VMs from it (or leave idle if VMs aren't moving over yet).
- Once nodes 2/3 join and Ceph goes live: wipe this pool, hand the disks to Ceph, migrate VMs onto Ceph-backed storage.